FS: Use two different speeds when checking for runout
When doing a PAT9125 "soft check", use two different speeds between retraction and extrusion. This increases the chances that we can track the surface.
This commit is contained in:
parent
3be859ece9
commit
bd0544fe9e
@ -624,7 +624,7 @@ void fsensor_update(void)
|
||||
fsensor_oq_meassure_start(0);
|
||||
float e_tmp = current_position[E_AXIS];
|
||||
current_position[E_AXIS] -= 3;
|
||||
plan_buffer_line_curposXYZE(200/60, active_extruder);
|
||||
plan_buffer_line_curposXYZE(250/60, active_extruder);
|
||||
current_position[E_AXIS] = e_tmp;
|
||||
plan_buffer_line_curposXYZE(200/60, active_extruder);
|
||||
st_synchronize();
|
||||
|
Loading…
Reference in New Issue
Block a user