Commit Graph

1347 Commits

Author SHA1 Message Date
Voinea Dragos
0cbc759d8b Second attempt at retrieving the SN from the 32u2 IC 2021-06-21 07:24:41 +02:00
Yuri D'Elia
09e935d27b Fix two new explicit case fallthru warnings 2021-06-21 06:52:52 +02:00
Yuri D'Elia
c096462aab Clarify statement by adding extra braces 2021-06-21 06:52:52 +02:00
Yuri D'Elia
051f03119b Fix misleading indentation warnings by expanding tabs 2021-06-21 06:52:52 +02:00
Yuri D'Elia
f2fe57bfc0 Fix unused static declaration warnings
Guard declarations using the appropriate defines
2021-06-21 06:52:52 +02:00
Yuri D'Elia
eafdf6c216 Also move host_keepalive to manage_inactivity()
This avoids the "busy" output interleaving with regular output in very
rare scenarios.

We should focus in finding which calls are not using manage_inactivity()
properly instead of working it around.
2021-06-21 06:46:24 +02:00
Yuri D'Elia
29322d4bf3 Move host_autoreport() to manage_inactivity()
This makes autoreport work more consistently.
2021-06-21 06:46:24 +02:00
Yuri D'Elia
5c8a231ed6 Move autoreporting out of the temperature ISR
Code running in the temperature ISR needs to be fully reentrant, which
is hard to track down.

Move autoreporting to the main processing loop. This can make the
autoreporting slower or pause at times, but removes the reentrant
restriction, which allows us to use printf_P.
2021-06-21 06:46:24 +02:00
D.R.racer
6bb7c0e3d3 Farm workaround M1 message
Farmers want to abuse a bug from the previous firmware releases
- they need to see the filename on the status screen instead of "Wait for user..."
So we won't update the message in farm mode...
2021-05-25 09:45:42 +02:00
DRracer
80e248662c
Merge pull request #3079 from 3d-gussner/PFW-1189
PFW-1189 Pre-release tasks
2021-04-29 16:33:18 +02:00
DRracer
89386036e6
Merge pull request #3137 from leptun/PFW-1239_fix_M23_subroutine_issue
Do not allow M23 to run subroutines
2021-04-29 15:06:33 +02:00
DRracer
a3b392d96c
Merge pull request #3130 from DRracer/move-alldata-2-end
Move All Data into last position in Factory Reset menu
2021-04-29 10:08:32 +02:00
Voinea Dragos
8610d0a850 Do not allow M23 to run subroutines 2021-04-29 10:59:21 +03:00
DRracer
7c914ec2d1
Merge pull request #3125 from leptun/PFW-1238_fix_M105_from_SD
Fix M105 from SD
2021-04-29 09:12:05 +02:00
D.R.racer
5089b2cddb Move All Data into last position in Factory Reset menu 2021-04-28 06:43:54 +02:00
3d-gussner
686054b95e Changed x of 4 and y of 9 to x/4 and y/4
Added `Iteration` translation
2021-04-27 20:22:28 +02:00
3d-gussner
b8ae08fd3d Update x of 4 and x of 9 messages so longer text can be used. 2021-04-27 07:18:52 +02:00
3d-gussner
af519626aa Define MSG_FS_V_04_OR_NEWER and MSG_FS_V_03_OR_OLDER c=14 2021-04-26 14:21:33 +02:00
3d-gussner
466de83ae0 Remove white spaces in messags which saves ~62bytes 2021-04-26 07:22:22 +02:00
Marek Bel
aa45091400
Scale extruder motor current linearly with speed. (#2813)
Scale extruder motor current linearly with speed.

49% less heating when running at low speed and standstill, 4% more torque at maximum extrusion rate (15mm^3/s), 15% more torque in high speed movements (un/retractions).

StealthChop mode is used for low speeds (below 900mm/min)
spreadCycle is used above. Transition speed is well above maximum extrusion rate of 15mm^3/s (275mm/min) so mode transition is not expected to be visible on printed surface.

StealthChop is expected to improve printed surface quality (less artifacts).

Warning you can burn extruder motor if it is not the same impedance as original Prusa i3 Extruder stepper motor. There is no current feedback in low speed so lower impedance motor can be burned by over current.

Even there is no direct current feedback, there is no risk for original motor thermal runaway, as motor resistance increases with temperature, current decreases.

Standstill peak phase current is expected to be 500 mA and linearly increase with speed to 970 mA at 900mm/min where spreadCycle constant current regulation takes over and keeps peak current at 805 mA to maximum speed possible.

As motor heating increases with current squared, lowering low speed current from 700mA to 500mA decreases heating 49% in thate mode, where motor spends most of the time.

Enable E-motor cool mode in farm mode only (and experimental menu) - the experimental menu is visible AND the EEPROM_ECOOL variable has a value of the universal answer to all problems of the universe - i.e. two conditions must be met at the start of the FW to enable the E-cool mode. If the user enables the experimental menu, sets the E-cool mode and disables the menu afterwards, on the next start of the FW the E-cool mode will be DISABLED. This is still subject to discussion how much obscure (security through obscurity) we'd like this option to have .

Additional stuff:
* Add serial debug msg to verify if E-cool mode is on
* Avoid access to E-cool mode switch on machines without TMC2130
* Do not allow only M907 E in case of E-cool mode+warn the user on the serial line that the command was skipped

Co-authored-by: D.R.racer <drracer@drracer.eu>
2021-04-23 16:06:28 +02:00
3d-gussner
403b340f19 Added EXTENDED_M20 to RepRap Gcode wiki M115 see https://reprap.org/mediawiki/index.php?title=G-code&type=revision&diff=189034&oldid=189033 2021-04-23 11:02:42 +02:00
Voinea Dragos
635bc442d6 Fix M105 from SD 2021-04-23 11:14:16 +03:00
3d-gussner
e18d688b64 Fix merge issues 2021-04-22 20:48:26 +02:00
3d-gussner
681bc560c9 Merge remote-tracking branch 'upstream/MK3_3.10.0' into PFW-1189 2021-04-22 20:43:54 +02:00
DRracer
00ce16ee55
Merge pull request #3121 from wavexx/reduce_m600_min_height
Revert/cleanup mininum extruder height during M600
2021-04-22 11:43:18 +02:00
Yuri D'Elia
daef5428d2 Rework gcode_M600_filament_change_z_shift to make it consistent
gcode_M600_filament_change_z_shift is almost useless, since it performs
what is already been done internally by filament_unload().

However it *does* cause the carriage to raise earlier during unload
compared to making the user wait after "press for unload".

Change it so the calculated Z height matches MIN_Z_FOR_SWAP.
2021-04-21 19:12:26 +02:00
Yuri D'Elia
8d04316497 Revert/cleanup mininum extruder height during M600
This change restores the minimum extruder height for filament purge
during M600 from the current 50mm back to 27mm from FW 3.9.

We do this by introducing a new option for unload_filament() to indicate
that the unload is part of an automatic swap, and in such cases avoid
raising more than absolutely necessary (this will _also_ come in handy
to avoid the extra purge in PR #2318 during M600).

A new define MIN_Z_FOR_SWAP is introduced for this purpose.
MIN_Z_FOR_UNLOAD is still used for manual lcd unload and for M702 and
hasn't been changed.
2021-04-21 19:07:58 +02:00
Alex Voinea
7d82cab125
Update doxygen 2021-04-20 09:16:56 +03:00
Alex Voinea
c4b70b82f3
Document M20 T parameter 2021-04-20 09:13:38 +03:00
Alex Voinea
1c0383c48f
Add capability report for extended M20 2021-04-20 09:03:22 +03:00
D.R.racer
7011014abb Save 16 bytes - pass ls_param by value to functions
... as ls_param is a 1-byte structure it is more conservative to pass it
to functions by value than by a pointer
2021-04-20 06:50:37 +02:00
Voinea Dragos
2129bcf315 M20 T 2021-04-19 14:48:50 +03:00
Yuri D'Elia
a5e4df390d Sync before/after setting mesh_bed_leveling_flag/homing_flag
mesh_bed_leveling_flag and homing_flag should be set only when the
planner is empty as a consequence of #3100, since any operation executed
*while* the mbl/homing flag is set is considered part of the compound
instruction that generated it (G80, G28, G30, G76).

Failure in doing so can result in instructions just prior being lost,
since they're incorrectly discarded (assumed to be redone).

G1  ; lost ..
G80 ; .. if PP happens here
2021-04-19 06:31:57 +02:00
DRracer
f9f6284c50
Merge pull request #3100 from wavexx/powerpanic_state_fixes
Fix PowerPanic and Crash Detection during homing and bed leveling
2021-04-07 18:19:50 +02:00
Yuri D'Elia
61faa49cbb Fix buffer overflow in buf
Fix cmd overflow introduced in 186ce0f.

With a precision of %f being .6 and assuming a maximum (theoretical)
acceleration of 99999 we need 47 bytes including terminating byte.

Round it to 48
2021-04-07 15:57:50 +02:00
Alex Voinea
9454f9d8ec Rename w25x20cl to xflash 2021-04-06 10:16:47 +02:00
Yuri D'Elia
449d181971 G80: handle power panic
This is handled in the same way crash detection is handled: homing/mbl
invalidates saved_target _and_ current position.

Fixes PP recovery during MBL and homing.
2021-04-06 02:20:00 +02:00
Yuri D'Elia
b46a52ffa8 G80: Handle crash detection
At a higher level, crash detection will repeat the last gcode command.

Some commands such as G28 or G80 need to be repeated in full and require
special handling.

In such cases, do not store the saved target coordinate (which is fake
in such cases) and invalidate the saved position.

This fixes the last coordinate of the first G1 move after recovery.

We also avoid moving from the origin when the saved position is
invalidated, which is not strictly necessary, but saves some time.
2021-04-06 02:00:47 +02:00
Yuri D'Elia
a5530593fa G80: preserve lcd status and message when aborting
Restore the old status just before returning, so that the subsequent G80
can restore the first (initial) message correctly.
2021-04-06 00:31:56 +02:00
Yuri D'Elia
5923276a86 G80: correctly abort during crash detection
Crash detection is handled at a higher level (which automatically
repeats the current command), however we still need to abort the current
command correctly.

Handle XY crashes by checking the planner status after st_synchronize().
2021-04-06 00:31:29 +02:00
Yuri D'Elia
5da39df968 G80: Use consistent XY axis feedrate 2021-04-06 00:10:33 +02:00
Yuri D'Elia
ce2e35d14d Move G80 into it's own function
No actual changes done in the function in this, besides break->return.

In G28, simply call the new function instead of using goto, making the
code more readable.

Also remove the senseless comments in G28 about command queuing (dating
back to when G80 was queued instead of being executed).
2021-04-05 23:35:17 +02:00
Yuri D'Elia
d2be40491b PP recovery: clamp initial position to software endstops
As done when initializing the printer from a cold start, we need to
clamp the starting position to software endstops before setting the
planner position since 0,0 is frequently out-of-bounds.

This avoids an useless move during recovery that can cause a crash:

- Initial X is set to be 0
- G1 performed by homing will clamp X>=0, resulting in a positive shift
- If X is already at max X (extruder being parked due to PP), this will
  slam at X+, causing an immediate crash.
2021-04-05 22:11:06 +02:00
Yuri D'Elia
6a61c26955 Removed unused crashdet_stop_and_save_print2 2021-04-05 20:04:50 +02:00
3d-gussner
b74e1d6062 Update RepRap url for M123 2021-04-01 19:48:14 +02:00
3d-gussner
e12c1dde5c Updated RepRap Wiki and removed the @todos 2021-04-01 19:06:31 +02:00
3d-gussner
c0869efc76 Define #MSG_MK3S_FIRMWARE_ON_MK3 c=20 r=4, #MSG_MK3_FIRMWARE_ON_MK3S c=20 r=4 2021-03-31 07:36:26 +02:00
3d-gussner
b52d87e9a5 Define #MSG_Z-LEVELING_ENFORCED c=20 r=4 2021-03-31 07:02:42 +02:00
3d-gussner
7f3fe6740b Update #MSG_NO_MOVE c=20 2021-03-30 18:46:56 +02:00
DRracer
a251dcc14e
Merge pull request #3064 from 3d-gussner/PFW-1222
PFW-1222: Disable M120 M121
2021-03-30 10:09:47 +02:00