3d-gussner
6c6f6abfc0 Rename EN_ONLY to EN_FARM
remove DEBUG/DEVEL/ALPHA/BETA lcd warning

Fix cherry-pick issues
2022-09-29 17:47:05 +02:00
D.R.racer
996f9943a1 Extract PRINTER_ACTIVE into a noinline function
Having the original PRINTER_ACTIVE macro copied at multiple spots doesn't make sense.
Refactoring it into a non-inline function saved ~400 bytes of code.
It should be safe in terms of performance, all occurrences are at non-time critical spots.
2022-09-14 07:31:39 +02:00
Alex Voinea
ec84c22865 Remove unused define 2022-08-30 13:57:43 +02:00
Alex Voinea
bef7b086e3 Isolate the entire farm and statistics code 2022-08-30 13:57:43 +02:00
Alex Voinea
671519caf3 Optimize by hand since the lto is still stooopit
saves ~100B
2022-08-24 20:19:26 +03:00
Alex Voinea
05bd1ba57f Multi-segment pause resume initial 2022-08-24 20:19:26 +03:00
Yuri D'Elia
1eb7871bab Also save fan speeds during a thermal error pause
Similarly to temperatures, the fan speed is overwritten and needs to be
restored appropriately.
2022-07-25 17:30:22 +02:00
Yuri D'Elia
eccfcd7424 Save/restore temperatures during a thermal pause
Re-used saved_* vars (as normally used during the paused state) to
backup the original values when a thermal error occurs.
2022-07-25 17:30:22 +02:00
Yuri D'Elia
9ef80226c9 Rename argument of ThermalStop for clarity 2022-07-25 17:30:22 +02:00
Yuri D'Elia
6751586db6 Cleanup original thermal error handlers.
Remove useless repeated calls to disable heaters and turn on the fans,
since this is done at a higher level.

Avoid repeating messages on the serial. Do it just once.

Make a critical alert sound unconditionally.
2022-07-25 17:30:22 +02:00
Yuri D'Elia
ea0840dee9 Refuse to run TM calibration if the printer is not idle 2022-07-25 17:30:22 +02:00
Yuri D'Elia
cc96a47e7f Implement temperature model autotuning
Calibrate C/R values via univariate minimization using golden section.
This is done in several passes:

- Bootstrap C by setting an initial high R value
- Calibrate R at the requested working temperature
- Cooldown
- Refine C to the final value
- Estimate R losses for a subset of fan speeds
- Interpolate remaining values to speed-up the process

This results in robust values which are tailored to the current
filtering constants, and avoid having to sample for an extended
time to reach the required resolution.

The refining pass could avoid cooldown if the recording buffer was at
least twice as large, so that we could record both the heating and the
steady-state, saving _considerable_ time.
2022-07-25 17:30:22 +02:00
Yuri D'Elia
82e221e3c7 Remove ADC pullup checks
Setting pullups on the ADC should trigger the model-based check, making
this redundant and wasteful.

Keep the DEBUG_PULLUP_CRASH menu so that we can verify this behavior in
the future.
2022-07-25 17:30:21 +02:00
Yuri D'Elia
13163e9fbf Move millis_nc to system_timer.h 2022-07-18 17:53:27 +02:00
Yuri D'Elia
f8de274db3 Split fan checks out of temperature.cpp 2022-07-18 17:53:27 +02:00
Yuri D'Elia
e37435b53f Merge remote-tracking branch 'upstream/MK3_3.11.1' into mk311_sync 2022-07-04 16:14:23 +02:00
Alex Voinea
b52597f1b2
Merge branch 'MK3_3.11.1' into MK3_3.10.2 2022-04-07 14:05:34 +02:00
Alex Voinea
97c371e5e8 Make the "ln" functions no-inline.
Save 348B of flash
2022-02-27 20:58:56 +01:00
Alex Voinea
a6331d22c8 Remove ancient SNMM code in the MK3 branch 2022-02-15 15:58:33 +01:00
Alex Voinea
4ec8781df2 Fix usb print timer 2022-02-13 22:52:49 +01:00
Guðni Már Gilbert
459570ab66 Change prusa_stat_printerstatus parameter to uint8_t
Also changes status_number global variable to uint8_t

Changes save 80 bytes of flash and 1 byte of SRAM (Arduino IDE 1.8.19)
2022-02-02 18:35:52 +00:00
Alex Voinea
b7806bf25f Crash if pullups get enabled on the thermistor inputs 2022-02-01 12:34:07 +01:00
Guðni Már Gilbert
9bf45773f9 Merge remote-tracking branch 'upstream/MK3' into rebase-testing-ground-v2 2022-01-30 11:43:16 +00:00
Guðni Már Gilbert
f8847edca6 Remove one unused variable
Saves 1 byte of SRAM

The variable is only assigned a value but is never used.
2022-01-30 11:39:28 +00:00
Guðni Már Gilbert
a940c364c9 Create enum class for heating_status variable 2022-01-30 11:39:27 +00:00
Guðni Már Gilbert
60c9640602 Change heating_status_counter to uint8_t
It has a max value of 14

Saves 28 bytes of flash and 1 byte of SRAM
2022-01-30 11:39:26 +00:00
Guðni Már Gilbert
22f23dff36 Change heating_status to uint8_t
Saves 66 byte of flash and 1 byte of SRAM
2022-01-30 11:39:26 +00:00
Guðni Már Gilbert
2d614a8d41 Change usb_printing_counter to uint8_t
It is assigned max value of 10

Saves 26 byte of flash and 1 byte of SRAM
2022-01-30 11:39:26 +00:00
Guðni Már Gilbert
42778cae83 Remove unused kicktime timer
The variable is only set and never actually used

Saves 8 bytes of flash and 4  bytes of SRAM
2022-01-30 11:39:25 +00:00
Guðni Már Gilbert
37fd9d1b11 Convert NcTime to ShortTimer
The variable is only used in ultralcd.cpp so I made it static there
and deleted it from Marlin_main.cpp

Saves 24 bytes of flash and 1 byte of SRAM
2022-01-30 11:39:25 +00:00
DRracer
0be90dc5d1
Merge pull request #3320 from prusa3d/MK3_3.10.1
Merge MK3_3.10.1 into MK3 after release
2021-12-17 14:02:13 +01:00
Yuri D'Elia
a3915b57b9 Improve temp_runaway_stop robustness
Remove most of the duplicated code inside temp_runaway_stop(),
making it identical to the other temperature handlers.

Move the lower-level functions required to stop the entirety of the
machine into UnconditionalStop(). Reuse this function inside
lcd_print_stop().

Set the LCD alert message before calling Stop(), as done in other safety
handlers, so that the error is visible while the printer is stopping.

This also avoids other temporary status messages to appear before
the real issue is shown and/or STEALING the first CRITICAL alert
level before we do.
2021-12-07 19:25:34 +01:00
Guðni Már Gilbert
2554d21925 Use uint8_t when using axis enum
Saves 76 bytes of flash memory
2021-08-02 12:20:10 +00:00
Guðni Már Gilbert
6aee17b4ca lcd_change_fil_state has two extern's in Marlin.h, only one needed. 2021-07-20 09:12:14 +02:00
Guðni Már Gilbert
eb9c8c8c20 Improve mc_arc() parameters
- Make the mc_arc() function declaration consistent with the definition
- isclockwise is supposed to be bool type, given how it is used.
2021-07-20 09:03:50 +02:00
Yuri D'Elia
050cf72e98 Move stack checking to the temperature ISR
Now that the stack_error function is truly minimal,
we can check for stack errors much more frequently.

Also move away stack_error from ultralcd to Marlin_main.
2021-06-12 15:23:33 +02:00
DRracer
8ac1d5b95e
Attempt to workaround the M73 C0|D0 visual issue (#3067)
Attempt to workaround the M73 C0|D0 visual issue

This is an attempt to enable alternation of time to print finish and time
to color change even in the last minute of time to color change, i.e. be
able to print "0:00C".

The proposed solution leverages the capability of the current FW to read
float values from the C|D parameter. This could have the raw benefit of
being able still to alternate this time on the LCD as "0:00C" (or
"<1min") if the slicer sends a non-zero but <1 time right before the
color change.

Co-authored-by: D.R.racer <drracer@drracer.eu>
Co-authored-by: 3d-gussner <3d.gussner@gmail.com>
2021-03-19 10:18:28 +01:00
Yuri D'Elia
14a1a93bc8 Include probing/MBL in the PRINTER_ACTIVE check
This prevents to perform disruptive actions during homing or between MBL
probes, which would result in a failure.
2021-02-25 17:33:59 +01:00
3d-gussner
d063ffb141 Add parameter D to gcode M73 for silent/stealth mode 2021-02-11 07:47:43 +01:00
3d-gussner
91c767b0f2 Reduce code size 2021-02-11 07:47:43 +01:00
3d-gussner
cb61436093 Add remaining time to change/pause/user interaction to LCD Info screen
- Add parameter `C` to gcode `M73`
- LCD Info screen switches to change time if last `M73` gcode contains `C` parameter
  - Examples:
    - `M73 P5 R120` will display on LCD ` SD  5%      02:00R ` if it is printing at 100% speed
    - `M73 P5 R120 C60` will display on LCD ` SD  5%      01:00C ` if it is printing at 100% speed

Slicers can generate "Time to change/pause/user interaction" using `C<mins:0-65535>` parameter to "overwrite" the remaining print time.
To switch between time to change and remaining time just send in intervals `M73` with or without `C` parameter.
2021-02-11 07:47:43 +01:00
Voinea Dragos
52f7a71dce More fixes that were extracted from #2405 2021-02-06 14:59:11 +02:00
Alex Voinea
896f4e1dd1 Fix compile error 2021-02-02 19:14:05 +02:00
Alex Voinea
f6ae379077 Fix dir_names array definition. Prevents overrun 2021-02-02 19:08:44 +02:00
Alex Voinea
2f4119a6d7 M552 - Printer IP address 2021-02-02 13:21:16 +02:00
3d-gussner
9264454d3a Gcode M123 only if FANCHECK and TACHOs are defined
Gcode `M155` added parameter "C" to activate auto-report for temperatures, fans and positions
Updated doxygen
@todo Update RepRap Wiki
@todo improve code
2021-01-19 09:01:46 +01:00
3d-gussner
a064ce4722 Add gcode M123 Tachometer value 2021-01-10 15:15:44 +01:00
Alex Voinea
4abf1f436a Gracefully dump the queue + fixes to fancheck 2020-11-09 21:49:56 +02:00
Alex Voinea
ff56ece6f8 Remove redundant get_command prototype 2020-11-09 21:49:56 +02:00
Alex Voinea
eb007c35d2