Commit Graph

963 Commits

Author SHA1 Message Date
PavelSindler
27cc5e51c3 removed duplicit declaration of prusa_statistics function 2018-03-13 19:12:36 +01:00
PavelSindler
5d389a2c36 Farm mode: when print finishes, ask which filament was used for print; statistics modified 2018-03-13 19:11:02 +01:00
PavelSindler
a3ad74a6be status screen fix 2018-03-13 19:08:19 +01:00
PavelSindler
8ec3c0fd7e removed "Printer disconnected" message 2018-03-13 18:50:56 +01:00
PavelSindler
f45f206faf sorting files disabled in farm mode, start printer status needs reponse from monitoring 2018-03-13 18:50:11 +01:00
PavelSindler
ddeb7b8c84 statistics improved, initial version of function which forces user to connect printer to monitoring 2018-03-13 18:43:42 +01:00
Robert Pelnar
16f9f35451 static_assert replaced with error directive 2018-03-13 16:47:38 +01:00
PavelSindler
0c97f46f25
Merge pull request #551 from XPila/MK3-new_xyz_cal
New XYZ calibration with image processing
2018-03-13 16:17:50 +01:00
XPila
a23ac6db7d
Merge pull request #550 from mkbel/safety_timer_MK3
Safety timer (disable heaters after 15min idle)
2018-03-13 15:03:45 +01:00
XPila
701dc55f4e
Merge pull request #549 from mkbel/safety_timer
Safety timer (disable heaters after 15min idle)
2018-03-13 15:02:09 +01:00
XPila
f487691070
Merge pull request #536 from mkbel/menu_return
Menu return
2018-03-13 14:30:48 +01:00
PavelSindler
98e96c9182
Merge pull request #457 from bubnikv/MK3_fast_dbg
Mk3 fast dbg
2018-03-13 14:13:29 +01:00
Robert Pelnar
65a91b366d New XYZ calibration with image processing 2018-03-13 12:55:35 +01:00
Marek Bel
6b08cdeaf1 Safety timer (disable heaters after 15min idle) 2018-03-12 23:45:10 +01:00
Marek Bel
262e800db7 Safety timer (disable heaters after 15min idle) 2018-03-12 23:35:50 +01:00
Christoph Stahl
1df91e5656 MK3 Add Gcode to wait for minimum PINDA temp
The PINDA temperature compensation is defined for values above 35C. To achieve an optimal first layer consistently it is vital to start the print with a temperature of >= 35C on the pinda probe.
When doing a manual pinda temperature calibration it is necessary to begin homing and mesh bed leveling at an exact temperature. This gcode is perfect for this.

Example startup code:

G28 W ; home all without mesh bed level
G0 Z50 ; raise Z to not heat PINDA before bed is warm
M104 S215 ; set extruder temp
M140 S60 ; set bed temp
M190 S60 ; wait for bed temp
M109 S215 ; wait for extruder temp
G0 X50 Y50 Z0.15 ; this is a good PINDA heating position
M666 S35 ; the new code - wait until PINDA is >= 35C
G28 W ; home all without mesh bed level
G80 ; mesh bed leveling

See my forum post later for more explaination on my manual temperature calibration procedure. I will link it then.
2018-03-09 20:46:07 +01:00
XPila
f7944c3821
Merge pull request #541 from XPila/MK3
version changed
2018-03-09 14:24:26 +01:00
Robert Pelnar
66dc65ecd4 version changed 2018-03-09 14:15:47 +01:00
PavelSindler
dd771b1481
Merge pull request #539 from PavelSindler/MK3_for_merging
version changed
2018-03-08 15:19:13 +01:00
PavelSindler
d512c9c9c2 version changed 2018-03-08 14:48:01 +01:00
PavelSindler
20031fb252
Merge pull request #538 from XPila/MK3
Temperature calibration - remove steel
2018-03-07 22:11:19 +01:00
Robert Pelnar
976e5a6a19 Temperature calibration - remove steel 2018-03-07 21:45:55 +01:00
PavelSindler
edb3764c62
Merge pull request #537 from PavelSindler/MK25_selftest
changed version
2018-03-07 21:02:56 +01:00
PavelSindler
b902d91760 changed version 2018-03-07 21:02:07 +01:00
Marek Bel
b41d680adf Replace problematic character in comment. 2018-03-07 20:58:15 +01:00
Marek Bel
8ff028820a Remove redundant parameter. 2018-03-07 20:55:01 +01:00
XPila
fb5b7e9f7d
Merge pull request #535 from PavelSindler/x_axis_fix
Dont use homing currents in axis selftest
2018-03-07 20:46:34 +01:00
PavelSindler
abb9aa0a16 not using homing currents in axis selftest 2018-03-07 20:42:15 +01:00
Marek Bel
2a53686d2f Document valid usage of lcd_goto_menu(), remove redundant parameter. 2018-03-07 20:40:59 +01:00
Marek Bel
1aba608133 Document valid usage of lcd_goto_menu(), wrap lcd_second_serial_set() by HAS_SECOND_SERIAL_PORT macro. 2018-03-07 18:30:33 +01:00
Marek Bel
0c961dedc4 Reset menu stack in lcd_return_to_status().
Mark menuStack.reset() as redundant in lcd_status_screen(), but leave it there to be sure.
2018-03-07 18:15:24 +01:00
Marek Bel
716098c434 Preserve position in menu move axis Extruder. 2018-03-07 17:27:27 +01:00
Marek Bel
d0a98dc6cc Document valid usage of lcd_goto_menu(). 2018-03-07 17:18:10 +01:00
Marek Bel
0871925353 Remove special handling of lcd_move_z after long button press. Convert lcd_move_z after long button press to ordinary menu_action_submenu.
Known bug (feature) is, that with current maximum stack depth, when long press is activated in menu > settings > move axis > Move X and then Move Z is deactivated, menu is returned to "move axis" and not to "Move X".
2018-03-07 17:03:17 +01:00
Marek Bel
77c3d7d7f7 Review and document lcd_adjust_bed_reset() lcd_goto_menu() usage. 2018-03-07 16:47:20 +01:00
PavelSindler
f41584524e
Merge pull request #534 from PavelSindler/M221_fix
Fix of a regression bug, caused by pre-calculating the extrudemultiply
2018-03-07 16:13:16 +01:00
bubnikv
6ba07a358b Fix of a regression bug, caused by pre-calculating the extrudemultiply
for precission and performance: calculate_extruder_multipliers()
has to be called after extrudemultiply is changed from the printer panel.
2018-03-07 16:08:19 +01:00
PavelSindler
33a7723fba
Merge pull request #533 from bubnikv/M221_fix
Fix of a regression bug, caused by pre-calculating the extrudemultiply
2018-03-07 16:03:50 +01:00
bubnikv
fb4230f80d Fix of a regression bug, caused by pre-calculating the extrudemultiply
for precission and performance: calculate_extruder_multipliers()
has to be called after extrudemultiply is changed from the printer panel.
2018-03-07 15:46:46 +01:00
PavelSindler
1566487cbd
Merge pull request #532 from XPila/MK25
SafetyTimer disabled
2018-03-07 14:16:52 +01:00
Robert Pelnar
e3967e444b SafetyTimer disabled
Watchdog disabled
watchdog.cpp and watchdog.h source code removed (using directly <avr/wdt.h>)
2018-03-07 14:13:34 +01:00
Marek Bel
b7df176a46 Preserve position in menu Live adjust Z. 2018-03-06 22:45:47 +01:00
Marek Bel
ed0e7a8b58 Preserve position in menu move axis. 2018-03-06 21:27:06 +01:00
Marek Bel
020269a83c Fix unable to go back from main menu to status screen. 2018-03-06 21:26:14 +01:00
Marek Bel
e551ed1f6e Replace lcd_goto_menu(...) by menu_action_back() in lcd_menu_fails_stats(); 2018-03-06 19:51:13 +01:00
Marek Bel
235803bc2a Move encoder stack to separate class MenuStack. Add menu record to MenuStack.
It was needed to add menuFunc_t menu to stack, as in some places in menu, it is impossible to hardcode parent menu. Example: lcd_babystep_z can be invoked both from main_menu() and settings_menu() depending on printer status.
2018-03-06 19:47:27 +01:00
XPila
55065cf124
Merge pull request #530 from PavelSindler/temp_cal_fix
steps per unit changed to 0.95%; changed temp cal. warnings, changed …
2018-03-06 18:26:37 +01:00
PavelSindler
c986ac14ec pinda thermistor pin changed 2018-03-06 18:09:25 +01:00
PavelSindler
27659ae69e steps per unit changed to 0.95%; changed temp cal. warnings, changed pin for PINDA probe 2018-03-06 16:48:39 +01:00
Robert Pelnar
e906405662 Merge remote-tracking branch 'upstream/MK25' into MK25 2018-03-06 15:12:34 +01:00