Attempt to workaround the M73 C0|D0 visual issue
This is an attempt to enable alternation of time to print finish and time
to color change even in the last minute of time to color change, i.e. be
able to print "0:00C".
The proposed solution leverages the capability of the current FW to read
float values from the C|D parameter. This could have the raw benefit of
being able still to alternate this time on the LCD as "0:00C" (or
"<1min") if the slicer sends a non-zero but <1 time right before the
color change.
Co-authored-by: D.R.racer <drracer@drracer.eu>
Co-authored-by: 3d-gussner <3d.gussner@gmail.com>
Further restrict babystep insertion when the lcd_update is enabled by
toggling homing_flag when probing Z (where Z shouldn't be touched
anyway as it would disrupt the measurement)
Also reset the encoder value during mesh leveling.
The code around these calls _requires_ that the steps are immediately
processed and/or added to the subsequent planner moves.
The only part that doesn't care about immediate insertion is the
direct user-insertion though the lcd encoder.
Another request from our Service dept. - the user shall be prevented
from skipping the intro wizard, because otherwise some preset/calibrated
features will look like not done - especially live-z calibration.
And since there are users, who send a machine to service to perform 1st
layer calibration only, they must not omit the Z-calibration at the
start after shipping.
As the `M0/M1` moved to the beginning of the parser
- parser would not be able to "find" `M1nn` command if the query was `M1` instead of `M1 `
- to be able to "stop/halt" without sending a string and display default message use gcode `M0`
- as there are no `M0nn` gcodes the parser can query `M0` without additional space needed as in `M1 `
- Add parameter `C` to gcode `M73`
- LCD Info screen switches to change time if last `M73` gcode contains `C` parameter
- Examples:
- `M73 P5 R120` will display on LCD ` SD 5% 02:00R ` if it is printing at 100% speed
- `M73 P5 R120 C60` will display on LCD ` SD 5% 01:00C ` if it is printing at 100% speed
Slicers can generate "Time to change/pause/user interaction" using `C<mins:0-65535>` parameter to "overwrite" the remaining print time.
To switch between time to change and remaining time just send in intervals `M73` with or without `C` parameter.
upon request from our Service dept. - it is to do the same stuff like
Shipping prep., but keep the printer's stats intact. Still, this has to
be verified and may undergo some further changes.
Acceleration settings need to be saved in UVLO, since these are often
changed/set during a print. This is especially important for travel and
retract acceleration, which is usually set once per-print.
Saving and restoring is not 100% correct.
We save the current front-end value, which might ahead of the backend
when UVLO is triggered. Print acceleration, likely the most significant,
should be saved in the block buffer to be accurate.
Acceleration needs to be restored after the UVLO Z repositioning is
performed, using an M204 command. This is correct, however we don't save
the _temporary_ max acceleration limits set via M201, which could be
higher than the saved limits (via M500). This could result in lower
clamped values compared to the original print.
Maximum acceleration/jerk/feedrate limits should _all_ be saved in UVLO
in the future.
Allow to separate extrusion and travel acceleration settings using M204,
as Marlin 1.1.x and 2.x does using M204 T.
This allows to reduce the number of instructions required during
printing, since resetting the acceleration for travel moves is no longer
required and can be done a single time during the print.
Provision for this parameter was pre-existing, but not implemented.
M204 has two forms: the lagacy format (Marlin <1.1):
M204 S[print-acc] T[retract-acc]
and the newer format:
M204 P[print-acc] R[retract-acc] T[travel-acc]
The distinction in the MK3 FW is done based on the presence of the P
parameter. If P is seen, the new format is adoped. In the new format
however, M204 T was ignored until this change.
To keep backward compatibility, M204 S[acc] will set both print and
travel acceleration, which is identical in behavior to recent versions
of Marlin.
This is an extension/optimization of PR #2956.
It uses the cached 512B block buffer to avoid heavy-weight read() in SdBaseFile.
Even though this principle allowed the AVR to skip ~600KB of data within ~5 seconds,
the impact on code base is huge, especially into well proven and long-term stable
parts like reading a file from the SD card.
The sole purpose of this PR is to show/verify the possibility of the AVR CPU
in relation to adding thumbnails into MK3 G-codes.
Moreover, this PR shall not be merged unless the missing/commented features
are restored - especially file seeking and M84 search.
PFW-1175
- code_seen("string") -> code_seen_P(PSTR("string")) saved >100B of RAM!
- serial print "." -> '.' saved some code
- extract commonly used string
- SERIAL_PROTOCOLLN("") -> SERIAL_PROTOCOLLN() as no argument is
necessary
Motivation:
- save some RAM joining the autoreport flags into 1 byte
- encapsulate the magic of setting bit masks/features into a class with
a stable public interface