XPila
701dc55f4e
Merge pull request #549 from mkbel/safety_timer
...
Safety timer (disable heaters after 15min idle)
2018-03-13 15:02:09 +01:00
XPila
f487691070
Merge pull request #536 from mkbel/menu_return
...
Menu return
2018-03-13 14:30:48 +01:00
PavelSindler
98e96c9182
Merge pull request #457 from bubnikv/MK3_fast_dbg
...
Mk3 fast dbg
2018-03-13 14:13:29 +01:00
Robert Pelnar
65a91b366d
New XYZ calibration with image processing
2018-03-13 12:55:35 +01:00
Marek Bel
6b08cdeaf1
Safety timer (disable heaters after 15min idle)
2018-03-12 23:45:10 +01:00
Marek Bel
262e800db7
Safety timer (disable heaters after 15min idle)
2018-03-12 23:35:50 +01:00
Christoph Stahl
1df91e5656
MK3 Add Gcode to wait for minimum PINDA temp
...
The PINDA temperature compensation is defined for values above 35C. To achieve an optimal first layer consistently it is vital to start the print with a temperature of >= 35C on the pinda probe.
When doing a manual pinda temperature calibration it is necessary to begin homing and mesh bed leveling at an exact temperature. This gcode is perfect for this.
Example startup code:
G28 W ; home all without mesh bed level
G0 Z50 ; raise Z to not heat PINDA before bed is warm
M104 S215 ; set extruder temp
M140 S60 ; set bed temp
M190 S60 ; wait for bed temp
M109 S215 ; wait for extruder temp
G0 X50 Y50 Z0.15 ; this is a good PINDA heating position
M666 S35 ; the new code - wait until PINDA is >= 35C
G28 W ; home all without mesh bed level
G80 ; mesh bed leveling
See my forum post later for more explaination on my manual temperature calibration procedure. I will link it then.
2018-03-09 20:46:07 +01:00
XPila
f7944c3821
Merge pull request #541 from XPila/MK3
...
version changed
2018-03-09 14:24:26 +01:00
Robert Pelnar
66dc65ecd4
version changed
2018-03-09 14:15:47 +01:00
PavelSindler
dd771b1481
Merge pull request #539 from PavelSindler/MK3_for_merging
...
version changed
2018-03-08 15:19:13 +01:00
PavelSindler
d512c9c9c2
version changed
2018-03-08 14:48:01 +01:00
PavelSindler
20031fb252
Merge pull request #538 from XPila/MK3
...
Temperature calibration - remove steel
2018-03-07 22:11:19 +01:00
Robert Pelnar
976e5a6a19
Temperature calibration - remove steel
2018-03-07 21:45:55 +01:00
PavelSindler
edb3764c62
Merge pull request #537 from PavelSindler/MK25_selftest
...
changed version
2018-03-07 21:02:56 +01:00
PavelSindler
b902d91760
changed version
2018-03-07 21:02:07 +01:00
Marek Bel
b41d680adf
Replace problematic character in comment.
2018-03-07 20:58:15 +01:00
Marek Bel
8ff028820a
Remove redundant parameter.
2018-03-07 20:55:01 +01:00
XPila
fb5b7e9f7d
Merge pull request #535 from PavelSindler/x_axis_fix
...
Dont use homing currents in axis selftest
2018-03-07 20:46:34 +01:00
PavelSindler
abb9aa0a16
not using homing currents in axis selftest
2018-03-07 20:42:15 +01:00
Marek Bel
2a53686d2f
Document valid usage of lcd_goto_menu(), remove redundant parameter.
2018-03-07 20:40:59 +01:00
Marek Bel
1aba608133
Document valid usage of lcd_goto_menu(), wrap lcd_second_serial_set() by HAS_SECOND_SERIAL_PORT macro.
2018-03-07 18:30:33 +01:00
Marek Bel
0c961dedc4
Reset menu stack in lcd_return_to_status().
...
Mark menuStack.reset() as redundant in lcd_status_screen(), but leave it there to be sure.
2018-03-07 18:15:24 +01:00
Marek Bel
716098c434
Preserve position in menu move axis Extruder.
2018-03-07 17:27:27 +01:00
Marek Bel
d0a98dc6cc
Document valid usage of lcd_goto_menu().
2018-03-07 17:18:10 +01:00
Marek Bel
0871925353
Remove special handling of lcd_move_z after long button press. Convert lcd_move_z after long button press to ordinary menu_action_submenu.
...
Known bug (feature) is, that with current maximum stack depth, when long press is activated in menu > settings > move axis > Move X and then Move Z is deactivated, menu is returned to "move axis" and not to "Move X".
2018-03-07 17:03:17 +01:00
Marek Bel
77c3d7d7f7
Review and document lcd_adjust_bed_reset() lcd_goto_menu() usage.
2018-03-07 16:47:20 +01:00
PavelSindler
f41584524e
Merge pull request #534 from PavelSindler/M221_fix
...
Fix of a regression bug, caused by pre-calculating the extrudemultiply
2018-03-07 16:13:16 +01:00
bubnikv
6ba07a358b
Fix of a regression bug, caused by pre-calculating the extrudemultiply
...
for precission and performance: calculate_extruder_multipliers()
has to be called after extrudemultiply is changed from the printer panel.
2018-03-07 16:08:19 +01:00
PavelSindler
33a7723fba
Merge pull request #533 from bubnikv/M221_fix
...
Fix of a regression bug, caused by pre-calculating the extrudemultiply
2018-03-07 16:03:50 +01:00
bubnikv
fb4230f80d
Fix of a regression bug, caused by pre-calculating the extrudemultiply
...
for precission and performance: calculate_extruder_multipliers()
has to be called after extrudemultiply is changed from the printer panel.
2018-03-07 15:46:46 +01:00
PavelSindler
1566487cbd
Merge pull request #532 from XPila/MK25
...
SafetyTimer disabled
2018-03-07 14:16:52 +01:00
Robert Pelnar
e3967e444b
SafetyTimer disabled
...
Watchdog disabled
watchdog.cpp and watchdog.h source code removed (using directly <avr/wdt.h>)
2018-03-07 14:13:34 +01:00
Marek Bel
b7df176a46
Preserve position in menu Live adjust Z.
2018-03-06 22:45:47 +01:00
Marek Bel
ed0e7a8b58
Preserve position in menu move axis.
2018-03-06 21:27:06 +01:00
Marek Bel
020269a83c
Fix unable to go back from main menu to status screen.
2018-03-06 21:26:14 +01:00
Marek Bel
e551ed1f6e
Replace lcd_goto_menu(...) by menu_action_back() in lcd_menu_fails_stats();
2018-03-06 19:51:13 +01:00
Marek Bel
235803bc2a
Move encoder stack to separate class MenuStack. Add menu record to MenuStack.
...
It was needed to add menuFunc_t menu to stack, as in some places in menu, it is impossible to hardcode parent menu. Example: lcd_babystep_z can be invoked both from main_menu() and settings_menu() depending on printer status.
2018-03-06 19:47:27 +01:00
XPila
55065cf124
Merge pull request #530 from PavelSindler/temp_cal_fix
...
steps per unit changed to 0.95%; changed temp cal. warnings, changed …
2018-03-06 18:26:37 +01:00
PavelSindler
c986ac14ec
pinda thermistor pin changed
2018-03-06 18:09:25 +01:00
PavelSindler
27659ae69e
steps per unit changed to 0.95%; changed temp cal. warnings, changed pin for PINDA probe
2018-03-06 16:48:39 +01:00
Robert Pelnar
e906405662
Merge remote-tracking branch 'upstream/MK25' into MK25
2018-03-06 15:12:34 +01:00
Robert Pelnar
a6f900fd3c
Merge remote-tracking branch 'upstream/MK25' into MK25
...
# Please enter a commit message to explain why this merge is necessary,
# especially if it merges an updated upstream into a topic branch.
#
# Lines starting with '#' will be ignored, and an empty message aborts
# the commit.
2018-03-06 15:11:50 +01:00
PavelSindler
366268412b
Merge pull request #529 from PavelSindler/M221_fix
...
Fix of calculate_extrusion_multipliers().
2018-03-06 13:04:49 +01:00
bubnikv
2b7e50e45b
Fix of calculate_extrusion_multipliers().
...
This is a fix of a bug made in the previous commit.
2018-03-06 13:03:38 +01:00
PavelSindler
15e7b88834
Merge pull request #528 from bubnikv/M221_fix
...
Fix of calculate_extrusion_multipliers().
2018-03-06 13:00:57 +01:00
PavelSindler
54749cbcba
Merge pull request #524 from mkbel/Add_fail_stats
...
Add fail statistics menu item for MK25.
2018-03-06 11:55:22 +01:00
PavelSindler
8384dc47c7
Merge pull request #521 from mkbel/MK3
...
Remove Rpi port menu item for MK25.
2018-03-06 11:54:02 +01:00
PavelSindler
115416dc60
Merge pull request #520 from mkbel/MK25
...
Remove Rpi port menu item for MK25.
2018-03-06 11:53:37 +01:00
PavelSindler
df9c737cf7
Merge pull request #527 from PavelSindler/xyz_cal_corrections_3
...
searching for point xy updated to be more reliable, max z error enlar…
2018-03-06 11:52:32 +01:00
PavelSindler
ee2de71d26
searching for point xy updated to be more reliable, max z error enlarged to speed up calibration
2018-03-06 11:51:31 +01:00