Commit Graph

3771 Commits

Author SHA1 Message Date
Alex Voinea
7ea00a7efd
Fix typo in page description 2020-01-15 15:31:28 +02:00
Alex Voinea
8449136520
Separate M117 from the TMC2130 commands 2020-01-15 15:31:14 +02:00
Alex Voinea
4a4d7976d1
Fix PRUSA typo 2020-01-15 15:30:48 +02:00
Alex Voinea
55f3e7acaf
Merge branch 'MK3' into MK3-Gcode_documentation 2020-01-15 15:12:18 +02:00
DRracer
27f6807bd5
Merge pull request #2416 from wavexx/fix_G92_e_reset
Fix incorrect usage of plan_set_e_position() in G92 E*
2020-01-15 12:52:13 +01:00
DRracer
7230b99448
Merge pull request #2393 from wavexx/sync_before_resume
Sync before resume
2020-01-15 12:49:56 +01:00
DRracer
1a8420f3f9
Merge pull request #2383 from wavexx/fix_usb_resume_check
Fix fan_check_error check in usb print resume
2020-01-15 12:48:48 +01:00
DRracer
43870c4028
Merge pull request #2368 from wavexx/unretract_after_lcd_pause
Unretract when resuming a paused print
2020-01-15 12:47:24 +01:00
Yuri D'Elia
bab756699f Fix incorrect usage of plan_set_e_position() in G92 E*
To maintain an accurate step count (which is required for correct
position recovery), any call to plan_set_position&co needs to be done
synchronously and from a halted state.

However, G92 E* is currently special-cased to skip the sync (likely to
avoid the associated performance cost), causing an incorrect E step
count and position to be set. This breaks absolute position recovery,
miscalculation of the LA factor and possibly other weird issues.

We rewrite the handling of G92 to always sync but still special-case the
frequent "G92 E0" for performance by using a free bit in the block flags.

To avoid a sync, we relay the request for reset first to the planner
which clears its internal state and then relays the request to the final
stepper isr.
2020-01-14 20:24:14 +01:00
DRracer
4c74866864
Merge pull request #1933 from prusa3d/enable_cutter
Enable MMU cutter.
2020-01-09 13:47:44 +01:00
DRracer
673499dcbc
Merge pull request #2404 from leptun/fix_lcd_stop
New lcd_print_stop function
2020-01-09 13:40:51 +01:00
Alex Voinea
32c9cd2307
Merge branch 'MK3' into fix_lcd_stop 2020-01-09 14:17:56 +02:00
DRracer
b088500eaf
Merge pull request #1909 from wavexx/MK3_LA15
Linear Advance 1.5 Returns
2020-01-09 11:22:06 +01:00
3d-gussner
f3668cab92 Merge remote-tracking branch 'upstream/MK3' into MK3-Gcode_documentation
Fix merge issues with G90 and G91
2020-01-08 15:47:38 +01:00
DRracer
df300a2488
Merge pull request #2403 from leptun/MK3_unknown_Z_mark
Show ? near Z value if the position is unknown
2020-01-08 14:55:37 +01:00
DRracer
e15d5e21f5
Merge pull request #2402 from leptun/MK3_sheet_on_status_screen
Do not show sheet on status screen if less than 2 are initialized
2020-01-08 14:42:29 +01:00
DRracer
2f2e415eae
Merge pull request #2382 from wavexx/fix_lcd_stop
Fix lcd "Stop" when used within a pause
2020-01-08 14:40:54 +01:00
DRracer
3ef1c52a0a
Merge pull request #2381 from wavexx/remove_relative_mode
Remove "relative_mode", only use "axis_relative_modes"
2020-01-08 14:39:43 +01:00
Alex Voinea
8b0f0695a8
Merge branch 'MK3_fix_shorter_sheet_name_on_status_screen' into MK3_sheet_on_status_screen 2020-01-08 15:31:33 +02:00
DRracer
4936e01d3d
Merge pull request #2395 from wavexx/always_raise_at_zmin
Improve raise_z_above to always raise when at Z_MIN
2020-01-08 14:30:48 +01:00
Alex Voinea
9abdf4e535
Show ? near Z value if the position is unknown 2020-01-08 13:46:51 +02:00
Alex Voinea
c5324291ad
Do not show sheet on status screen if less than 2 are initialized 2020-01-08 12:48:41 +02:00
Alex Voinea
d9e5283526
Fix pause->stop->PrintFromSD scenario 2020-01-07 21:02:13 +02:00
Alex Voinea
1996fc7940
Remove commented-out code 2020-01-07 20:43:56 +02:00
Alex Voinea
4422fc29f8
Set XYZ to absolute and E to relative 2020-01-07 20:42:21 +02:00
Alex Voinea
f8a0d5d773
Fix lcd_print_stop function 2020-01-07 19:54:06 +02:00
Alex Voinea
df0d781c20
Merge branch 'MK3' into fix_lcd_stop 2020-01-07 19:53:55 +02:00
Alex Voinea
b05ee33fc9
Merge branch 'MK3' into MK3_BED_LEVELING_PWM 2020-01-07 07:58:32 +02:00
Yuri D'Elia
853991865c Improve raise_z_above to always raise when at Z_MIN
When check_z_endstop is set, Z_MIN_PIN is checkend regardless of the
moving direction to support Z calibration. This prevents the ability
to use _just_ SG when moving upwards.

But since we know the extruder is at Z_MIN, it's always safe to raise
irregardless, so we can dodge the issue.
2020-01-02 18:07:30 +01:00
Yuri D'Elia
5660fcffb0 Do not enqueue a E/Z moves unless requested
Do not unconditionally enqueue a Z move if no move has been requested.
Since Z is calculated using the absolute current (saved) position and
scheduled for later execution, the queue order becomes relevant.
2019-12-30 14:49:07 +01:00
Yuri D'Elia
86696156af Improve K error checking, allow to manually reset the version
Properly check K independently for each version by delegating it to la10c_value()

Handle -1 as a special case to allow manual reset.
2019-12-30 14:31:39 +01:00
Yuri D'Elia
57be14fca6 Complete all pending moves before restoring a saved print 2019-12-30 13:30:06 +01:00
Yuri D'Elia
fd0ed1f0ea Move LA reset from G28 to G80, do not reset on 0
In preparation for #2161, use MBL (G80) as a "new print" boundary
instead of just re-homing to ensure the reset is issued only once for
each print.

Similarly, do not reset the autodetection when LA is disabled via M900
K0. This can/will be used during a print if different quality settings
are used for different filling roles.
2019-12-30 11:32:27 +01:00
Yuri D'Elia
d78636c308 Do not synchronize on M900
Since the advance factor is computed per-segment in LA15, there's no
need to stop the planner. Allow changing K freely at each segment.

This allows varying quality factors for different filling roles, see:
https://github.com/supermerill/Slic3r/issues/108

During pause/resume/crashdetect or powerpanic K might temporarily be out
of sync when used this way. If this becomes an issue, we might need to
store K for each block, as done for the feedrate.
2019-12-29 23:25:16 +01:00
Yuri D'Elia
f5d382f9f4 Remove useless st_synchronize calls when unparking 2019-12-29 22:20:24 +01:00
Yuri D'Elia
186f881600 Avoid calling fsensor_update() one level earlier
Move the common checks between filament sensors out of fsensor_update().

Disable the runout check if a saved state is already present (this check
was missing in the PAT9125 variant) as this is currently not supported.

Note that the CHECK_FSENSOR looks completely redundant besides
e_active().
2019-12-29 22:08:44 +01:00
Yuri D'Elia
bd80ee88a0 Set the IN_HANDLER busy state while checking the filament 2019-12-29 21:27:42 +01:00
Yuri D'Elia
97170ed68d Do not call process_commands() within fsensor_update()
Plan moves directly to reduce the required stack size.
2019-12-27 19:37:20 +01:00
Yuri D'Elia
fe4c00fb8a Lift the extruder when checking for the filament
This avoids leaving marks on the print
2019-12-27 19:35:08 +01:00
Yuri D'Elia
301d64042b Set fsensor_watch_runout earlier to prevent re-entry
Do not set/clear fsensor_watch_runout within fsensor_oq_meassure_start
which is used outside of fsensor_update where it could have a different
starting value.

Set it within fsensor_stop_and_save_print to immediately prevent
re-entry.
2019-12-27 19:34:36 +01:00
Yuri D'Elia
a31319888c Fix fan_check_error check in usb print resume
Also check for fan_check_error == EFCE_OK in addition to EFCE_FIXED.

Reorganize the check in order to fix both #if[n]def FANCHECK cases,
as similarly done in the SDSUPPORT case a few lines below.
2019-12-23 19:12:46 +01:00
Yuri D'Elia
7b29ce29b4 Add a Linear Advance 1.0->1.5 compatibility layer
Allow existing gcode using LA10 to transparently take advantage of LA15
by using a simple linear conversion function based on experimental
results with the MK3 implementation of linear advance.

Autodetect LA10 values based on the first M900 instruction contained in
the print. In order to support printing mixed files without resetting
the printer we also reset the autodetection status when starting a new
SD print and/or when explicitly disabling LA.

Since we cannot reliably detect whether a new print is started when
printing via USB, also reset the detection status when homing in G28,
which is generally performed once at each print. Note that this doesn't
clear the previous K value, it only allows a subsequent M900 to provide
LA10 values when printed after a LA15 file.
2019-12-21 23:22:35 +01:00
Yuri D'Elia
c0ae92cd2a Remove "relative_mode", only use "axis_relative_modes"
axis_relative_modes can cleanly handle G90/G91 and M82/M83 without the
need of "relative_mode" entirely.

Change G90/G91 to simply reset all axes according to the requested
state, which avoids to check two variables in get_coordinates(),
fixing the following incorrect handling:

G91   ; all axis relative
M83   ; set extruder absolute
G1 E1 ; should be an absolute move, but still relative
2019-12-20 18:47:30 +01:00
Yuri D'Elia
8d60e4d6db Merge remote-tracking branch 'upstream/MK3' into MK3_LA15 2019-12-18 18:28:41 +01:00
Alex Voinea
f071aec747
Fix sheet minimum width on the status screen 2019-12-18 08:52:25 +03:00
3d-gussner
46c06f7eee Updated it to use Arduino_Boards v1.0.3
and linked everything to prusa3d repositories
2019-12-17 14:05:39 +01:00
Yuri D'Elia
8d490f941a Make use of the CRITICAL_SECTION macros in lcd_print_stop 2019-12-16 16:39:20 +01:00
Yuri D'Elia
0cc68228f8 Unretract when resuming a paused print 2019-12-16 16:33:11 +01:00
DRracer
955c88cf68
Merge pull request #2370 from wavexx/no_resume_while_resuming
Do not allow to resume a print twice while waiting for the hotend
2019-12-16 16:26:02 +01:00
Yuri D'Elia
faa76df2fe Fix the "Stop print" behavior from the LCD
Correctly cleanup the printer state when stopping the current print:

- Disable interrupts while aborting the planner/queue to ensure
  new serial commands are not inserted while aborting
- _Always_ call planner_abort_hard() to interrupt any pending move!
- Clear the saved_target, which might be set when calling stop
  from within a paused state. Create a new function to clear the
  paused state for future use.
- Do not disable/reset the MBL: doing so will destroy the ability to
  restart correctly using M999.
2019-12-16 15:52:37 +01:00