This requires expanding the dcode_core address type to 32bit type,
thus enlarges the D2/D3 implementation as a result.
Still allow to save all the original space if D6 is disabled, for now.
Allow to read up to 0x21ff, which is the last byte of SRAM. Set default
starting address to 0x200, which is the first true byte.
0x0-200 is mapped to register/io space and could cause issues when read
from bi-directional registers.
Farmers want to abuse a bug from the previous firmware releases
- they need to see the filename on the status screen instead of "Wait for user..."
So we won't update the message in farm mode...
Scale extruder motor current linearly with speed.
49% less heating when running at low speed and standstill, 4% more torque at maximum extrusion rate (15mm^3/s), 15% more torque in high speed movements (un/retractions).
StealthChop mode is used for low speeds (below 900mm/min)
spreadCycle is used above. Transition speed is well above maximum extrusion rate of 15mm^3/s (275mm/min) so mode transition is not expected to be visible on printed surface.
StealthChop is expected to improve printed surface quality (less artifacts).
Warning you can burn extruder motor if it is not the same impedance as original Prusa i3 Extruder stepper motor. There is no current feedback in low speed so lower impedance motor can be burned by over current.
Even there is no direct current feedback, there is no risk for original motor thermal runaway, as motor resistance increases with temperature, current decreases.
Standstill peak phase current is expected to be 500 mA and linearly increase with speed to 970 mA at 900mm/min where spreadCycle constant current regulation takes over and keeps peak current at 805 mA to maximum speed possible.
As motor heating increases with current squared, lowering low speed current from 700mA to 500mA decreases heating 49% in thate mode, where motor spends most of the time.
Enable E-motor cool mode in farm mode only (and experimental menu) - the experimental menu is visible AND the EEPROM_ECOOL variable has a value of the universal answer to all problems of the universe - i.e. two conditions must be met at the start of the FW to enable the E-cool mode. If the user enables the experimental menu, sets the E-cool mode and disables the menu afterwards, on the next start of the FW the E-cool mode will be DISABLED. This is still subject to discussion how much obscure (security through obscurity) we'd like this option to have .
Additional stuff:
* Add serial debug msg to verify if E-cool mode is on
* Avoid access to E-cool mode switch on machines without TMC2130
* Do not allow only M907 E in case of E-cool mode+warn the user on the serial line that the command was skipped
Co-authored-by: D.R.racer <drracer@drracer.eu>
gcode_M600_filament_change_z_shift is almost useless, since it performs
what is already been done internally by filament_unload().
However it *does* cause the carriage to raise earlier during unload
compared to making the user wait after "press for unload".
Change it so the calculated Z height matches MIN_Z_FOR_SWAP.
This change restores the minimum extruder height for filament purge
during M600 from the current 50mm back to 27mm from FW 3.9.
We do this by introducing a new option for unload_filament() to indicate
that the unload is part of an automatic swap, and in such cases avoid
raising more than absolutely necessary (this will _also_ come in handy
to avoid the extra purge in PR #2318 during M600).
A new define MIN_Z_FOR_SWAP is introduced for this purpose.
MIN_Z_FOR_UNLOAD is still used for manual lcd unload and for M702 and
hasn't been changed.
If the printer was already being pre-heated but didn't reach the target
temperature yet and a new filament is being inserted, the LCD used to
display a "Preheating to load" message to block the loading until the
extruder is hot.
This message is currently missing, and the ">Cancel" option doesn't
display immediately either, depending on the extruder height.
This PR fixes this behavior, which was broken during an earlier update.
We now force-update LCD updates during the first (and _only_) time the
screen is setup, and push all messages _before_ the carriage is
eventually raised, so that ">Cancel" is shown immediately as well.
mesh_bed_leveling_flag and homing_flag should be set only when the
planner is empty as a consequence of #3100, since any operation executed
*while* the mbl/homing flag is set is considered part of the compound
instruction that generated it (G80, G28, G30, G76).
Failure in doing so can result in instructions just prior being lost,
since they're incorrectly discarded (assumed to be redone).
G1 ; lost ..
G80 ; .. if PP happens here
PR #2967 altered the way ``sdpos_atomic`` was set, causing issues in the
crashdetect/powerpanic recovery offset if the instruction being
recovered happens to contain a comment.
Previously ``sdpos`` was assumed to be a single byte prior to the last
read character. sdpos+1 would thus position the index to the next
instruction. With gcode-filtering in place, sdpos is left just before
the comment, while the actual read position is at the newline. This
causes to parser to resume in the middle of the comment.
Change the value returned by cardreader::get_sdpos() to always return
the last read position, as everybody expects (!!).
This avoids the +1, and correctly sets the resume position to the next
valid instruction without overhead.
Fix cmd overflow introduced in 186ce0f.
With a precision of %f being .6 and assuming a maximum (theoretical)
acceleration of 99999 we need 47 bytes including terminating byte.
Round it to 48
This is handled in the same way crash detection is handled: homing/mbl
invalidates saved_target _and_ current position.
Fixes PP recovery during MBL and homing.
At a higher level, crash detection will repeat the last gcode command.
Some commands such as G28 or G80 need to be repeated in full and require
special handling.
In such cases, do not store the saved target coordinate (which is fake
in such cases) and invalidate the saved position.
This fixes the last coordinate of the first G1 move after recovery.
We also avoid moving from the origin when the saved position is
invalidated, which is not strictly necessary, but saves some time.
Crash detection is handled at a higher level (which automatically
repeats the current command), however we still need to abort the current
command correctly.
Handle XY crashes by checking the planner status after st_synchronize().
No actual changes done in the function in this, besides break->return.
In G28, simply call the new function instead of using goto, making the
code more readable.
Also remove the senseless comments in G28 about command queuing (dating
back to when G80 was queued instead of being executed).
As done when initializing the printer from a cold start, we need to
clamp the starting position to software endstops before setting the
planner position since 0,0 is frequently out-of-bounds.
This avoids an useless move during recovery that can cause a crash:
- Initial X is set to be 0
- G1 performed by homing will clamp X>=0, resulting in a positive shift
- If X is already at max X (extruder being parked due to PP), this will
slam at X+, causing an immediate crash.