- Handle the conversion from the V1 calibration status to the V2 bitmap
for all past FW versions.
- Allow to run the wizard in "Restore" mode (for example during upgrade
or service prep) to complete any missing steps.
- Fix service prep to use the above feature by clearing the appropriate
calibration bits.
- Remove exceptions for FW 3.2.0.4 which can now be handled cleanly.
Simplify status tracking:
- S::Restore to continue to the next logical wizard item
- S::Finish for a successful failure
- S::Failed to exit while showing a failure
- Move calibration status/declarations to util.h
- Allows to query the status of each step independently without assuming
any order
- Allows to extend the calibration with new steps transparently
- Generalize force_selftest_if_fw_version() so we can check when upgrading
between arbitrary FW versions.
- Do not call update_current_firmware_version_to_eeprom() prematurely
when forcing self-test (if a reset happens before self-test completes,
the check would be incorrectly skipped on the next run).
If there is no running print, and the printer is Stopped, add a new
"Acknowledge error" menu entry to unlock the printer.
This simply calls lcd_print_stop(), which is identical in behavior to a
thermal error with a running print.
Set a menu block for fatal thermal errors instead of abusing
lcd_return_to_status() to kick the user out of the menus.
This now allows a thermal model error to be recoverable through menu
access.
We allow resuming from the LCD via start print and resume print,
it makes sense to clear the error on stop too.
For this reason distinguish whether the action is performed
automatically or manually (ie: interactively).
The error is only cleared when the command is run interactively.
Since M310 cannot change the heaters, allowing M310 S0 (and changing
parameters) allows to recover a usb-controlled printer which has been
locked-out due to bad model settings.
This prevents the ability to run gcode from the SD card.
In a thermal error with faulty values, and without serial access, this
is the only way to process an M310 instruction and recover.
Ensure that fan checks are reset and use the new speed at each step of
the calibration.
This also gives extra time to the fan to ramp-up from a cold start,
when a fancheck could previously start right *after* the speed change.
Should fix#3791
- Correctly sequence the enqueued commands in order to check for the
real calibration result.
- Perform autocalibration with self-check enabled.
- Only save/continue the wizard if autocalibration succeeds.
- Ensures repeated autotune attempts with self-check can't succeed due
to different starting conditions.
- Allows for a simpler workflow during selftest and wizard if autotune
fails.
Provide average calibrated values for all fan levels for MK3/MK3S
variants and enable the model by default.
This ensures the calibration step is not skipped unless explicitly
disabled.
Force-clear fan values during autotune to restore the previous
calibration behavior, as fan resistance levels can be too big and
prevent the autotune-with-selfcheck to fail.