Commit Graph

122 Commits

Author SHA1 Message Date
Yuri D'Elia
9ec0ac9c64 Always reset e_steps between blocks
If e_steps are scheduled, but not ticked, they're just lost.
Only carry over the pressure state.
2020-04-09 00:46:57 +02:00
Yuri D'Elia
e84f82a675 Rewrite filament sensor PAT9125 error handling
Rewrite the logic behind the "chunking"/error count behind the PAT9125.

Basic idea: check the _direction_ of movement returned by the optical
sensor and compare it to the direction of the stepper. To avoid doing
this continuosly (and because the optical sensor doesn't necessarily
have the accuracy to track small distances), do so in chunks.

Each time a chunk doesn't match the expected direction, increase the
error count.

Several improvements were done to the previous code:

- Increase the chunk window: this ensures that a filament with
  poor response returns an usable direction, while also moving the
  average return values from the sensor in the middle of the 12 bits
  available for maximum effectiveness.
- Since the returned values are more reliable, reduce the error count
  (1.25mm*4 = ~5mm before runout detection)
- Track _both_ positive and negative movement, although only trigger
  errors during extrusion (necessary due to several assumptions made
  in the mmu/unloading code)
- Do not reset the counters for each block: accumulate distances
  correctly, allowing detection of any block lenght.
2020-02-06 14:37:46 +01:00
Yuri D'Elia
5c4235b886 Correctly reset the PAT9125 filament counters
When the error count is cleared, the cumulative deltas as well as the
segment lenght which is kept inside the stepper isr need to be reset.

Introduce a helper function fsensor_reset_err_cnt to clear all the
required variables in one place which can be used in most cases
(the only exceptions being quality measument).

Introduce a new function st_reset_fsensor to also clear the segment
lenght within the isr.
2020-02-05 16:21:27 +01:00
Yuri D'Elia
6fbd632c84 Isolate all PAT9125-specific code, fix build on !MK3 variants
- Hide all prototypes related to PAT9125 to force all callers
  to check for the proper sensor, since the handling differences
  are substantial
- Remove unneeded lenght accounting from the stepper isr as as
  consequence.
- Keep detailed soft failure counts for the MK3 on the "last print
  failures" status screen, but fix build on variants without a PAT9125
  by fixing the lcd stats function.
2020-02-05 16:20:12 +01:00
Yuri D'Elia
bab756699f Fix incorrect usage of plan_set_e_position() in G92 E*
To maintain an accurate step count (which is required for correct
position recovery), any call to plan_set_position&co needs to be done
synchronously and from a halted state.

However, G92 E* is currently special-cased to skip the sync (likely to
avoid the associated performance cost), causing an incorrect E step
count and position to be set. This breaks absolute position recovery,
miscalculation of the LA factor and possibly other weird issues.

We rewrite the handling of G92 to always sync but still special-case the
frequent "G92 E0" for performance by using a free bit in the block flags.

To avoid a sync, we relay the request for reset first to the planner
which clears its internal state and then relays the request to the final
stepper isr.
2020-01-14 20:24:14 +01:00
Yuri D'Elia
5122f79a39 Merge remote-tracking branch 'upstream/MK3' into MK3_LA15 2019-12-04 17:27:23 +01:00
Marek Bel
219a5e0625 Initialize EEPROM_SILENT in one place both for MK3 and MK25 printers and make it more clear. 2019-10-03 21:25:52 +02:00
leptun
444daceca3 Move define as requested 2019-09-12 13:39:04 +03:00
leptun
78708903e8 Also update eeprom value 2019-09-12 07:16:31 +03:00
leptun
90e5f14309 Fix compile error on MK3 2019-08-30 13:02:00 +03:00
leptun
56c949b9af Fix typo 2019-08-30 12:14:43 +03:00
leptun
d8d0069f97 Fix MK2.x Default stepper power out of sync 2019-08-30 12:12:29 +03:00
Yuri D'Elia
18b8dc89e5 Merge remote-tracking branch 'upstream/MK3' into MK3_LA15 2019-08-04 17:06:34 +02:00
Yuri D'Elia
1435e4a68d Use the computed direction in fsensor_st_block_begin 2019-08-04 16:53:48 +02:00
DRracer
8b806f692e
Merge pull request #1664 from MRprusa3d/PFW-811
"disable_z()" for Delta PSU
2019-07-16 16:46:34 +02:00
Yuri D'Elia
b6bcb901f3 Correct initialization of eISR_Err
Further tweak the initial term to improve the linearity of the resulting
speed after BW filtering.
2019-06-27 13:21:39 +02:00
Yuri D'Elia
2e073527fb Also avoid E direction inversions while coasting 2019-06-19 14:28:04 +02:00
Yuri D'Elia
4b3af0d2df Respect minimum direction change delay 2019-06-19 13:22:44 +02:00
Yuri D'Elia
0239f4bce1 Update/compute advance steps inside calculate_trapezoid_for_block
Do not store the block e_D ratio, store directly the computed
compression factor so that we can recompute the advance steps
quickly and update them in sync with the acceleration rates.
2019-06-05 20:25:26 +02:00
Yuri D'Elia
048628083a Remove clear_current_adv_vars()
The pressure state is already reset implicitly at the end of each block,
meaning an extruder switch will never have to reset the internal state
anyway.

We clear the internal backpressure in the following conditions:

- when switching to a non-LA block
- when quickStop is called
- when the scheduler is idling (losing pressure)
2019-06-05 20:25:19 +02:00
Yuri D'Elia
7d33089d9a Remove use_advance_lead
The per-step state is kept implicitly using nextAdvanceISR,
while the current pressure is decoupled anyway.
2019-06-05 20:25:12 +02:00
Yuri D'Elia
cda9ed4a1d Reset LA state more carefully during stop conditions 2019-06-04 16:22:40 +02:00
Yuri D'Elia
1bed8cfa94 Don't call fsensor_st_next_block repeatedly during the last step
Rely on st_block_begin to perform a single call instead of calling
block_chunk for each advance tick in the last step
2019-06-04 16:22:33 +02:00
Yuri D'Elia
c50b1c0351 Rework the filament counter logic
- Move direction checks out of fsensor: fsensor_counter is now
  always in the same direction as e_steps
- Check the filament chunk after e_steps have been physically done,
  using the real e_step count so far
2019-06-01 22:08:00 +02:00
Yuri D'Elia
47d2562510 Typos 2019-05-26 21:06:29 +02:00
Yuri D'Elia
823f7b069c Fix filament sensor direction again 2019-05-26 21:06:22 +02:00
Yuri D'Elia
9d834925c0 Recalculate LA_phase correctly 2019-05-26 17:06:21 +02:00
Yuri D'Elia
3abb2188df Fixup initial error by defect 2019-05-26 16:59:45 +02:00
Yuri D'Elia
20694aeabc Save 316 bytes by avoiding advance_spread copies 2019-05-26 16:41:56 +02:00
Yuri D'Elia
a28fb65bb2 Optimize advance_spread further 2019-05-26 16:41:50 +02:00
Yuri D'Elia
6f6cef65b5 Revert "Correctly handle direction for the filament sensor"
This reverts commit aae03ad83e.
2019-05-26 16:41:37 +02:00
Yuri D'Elia
bddc3e84ab Use WRITE_NC directly in the isr 2019-05-25 21:52:06 +02:00
Yuri D'Elia
aae03ad83e Correctly handle direction for the filament sensor 2019-05-25 21:51:59 +02:00
Yuri D'Elia
935a798236 Speedup advance_spread for common divisors 2019-05-25 21:51:52 +02:00
Yuri D'Elia
fa7ecfc38e Check for serial roughtly in the middle of the stepper isr 2019-05-25 18:41:28 +02:00
Yuri D'Elia
282b502393 Improve the distribution of the advance steps 2019-05-24 17:08:32 +02:00
Yuri D'Elia
aae5cce28f Use the nominal frequency to merge ticks 2019-05-24 17:08:32 +02:00
Yuri D'Elia
c6dbcc494f Typo 2019-05-24 17:08:32 +02:00
Yuri D'Elia
a1be8b6784 Initialize current_adv_steps correctly
Initialize at 0 both on startup and on reset on regular (non-LA)
segments to avoid cumulating errors.
2019-05-24 17:08:32 +02:00
Yuri D'Elia
707849e6c4 Use a define instead of hard-coding a divider 2019-05-24 17:08:32 +02:00
Yuri D'Elia
a2fa8e5313 Rewrite the advance_isr scheduler 2019-05-24 17:08:32 +02:00
Yuri D'Elia
2d3fe3197c Move calc_timer into speed_lookup_table for planner reuse 2019-05-24 17:08:32 +02:00
Yuri D'Elia
520cb491b2 Move speed lookup defs into a separate source 2019-05-24 17:08:32 +02:00
Yuri D'Elia
ebdc5e35e7 Remove two more OCR1A direct manipulations
Use _NEXT_ISR and st_reset_timer to correctly reinitialize and
re-schedule the advance ticks.
2019-05-24 17:08:32 +02:00
Yuri D'Elia
cbf1a85ec3 Switch original LA implementation with LA1.5
This discards several Prusa optimizations for LA1.0.
We'll re-implement those later if needed.

Debugging is turned on.
2019-05-24 17:08:32 +02:00
Yuri D'Elia
bf0c60dd45 Factor-out some repetition into fsensor_step 2019-05-24 17:08:32 +02:00
Ondrej Tuma
b7fe43bf68 Deleted bad cols/rows definitions for translation. 2019-05-07 12:52:23 +02:00
MRprusa3d
4b1fc69088 "disable_z()" for Delta PSU III
stealthChop set if motor-disable (@ Z) required
2019-04-02 20:04:44 +02:00
Marek Bel
28f1e309a2 Fix compiler warning: 'old_x_max_endstop' defined but not used
Fix compiler warning: 'old_y_max_endstop' defined but not used
2019-03-05 17:44:47 +01:00
Robert Pelnar
eea755496b Conditional translation for SYSTEM_TIMER_2 because we want to have posibility to switch between old/new implementation.
Timing functions (millis, micros and delay) replaced in whole source, defined in Marlin.h.
This commit enables original implementation (SYSTEM_TIMER_2 undefined)
Verified with passed complete wizard process.
2019-01-27 22:48:51 +01:00